Guerbet Optivantage DH Features: Dual Head CT Injector Specifications and Performance

Written by: Spectrum Xray /
/
November 19, 2025

Key Takeaways

  • The Guerbet Optivantage DH is an FDA 510(k)-cleared dual-head CT injector positioned as a mature, workhorse system for contrast-enhanced CT imaging across high-volume radiology environments.
  • Independent syringe drives, a 0.1–10.0 mL/sec flow rate range, pressure limits up to 350 psi, and flexible syringe capacities support everything from low-dose pediatric studies to high-flow CT angiography protocols.
  • Workflow-focused features such as multi-use day-sets for up to 24 hours, auto-fill, auto-purge, auto-home, and optional ceiling mounts help departments save time, reduce disposables, and optimize scanner utilization.
  • Safety and dose-management technologies, including Patency Check®, tilt enable safeguards, air and pressure monitoring, and OptiBolusⓇ software (reducing contrast volume by up to 40%), enhance both patient protection and image quality.
  • Connectivity via CAN class 4 and relay interfaces, RFID-enabled syringe tracking, Timing Bolus® synchronization, and automated data capture integrate the injector into CT scanners and radiology IT systems for efficient, data-rich workflows.

The Guerbet Optivantage DH is a dual-head CT injector engineered to deliver precise, programmable contrast and saline injections across a wide range of CT protocols. With independent syringe drives, broad flow and pressure ranges, and integrated safety features, it supports everything from routine body CT to high-demand vascular, cardiac, and multiphase studies. 

Beyond its core specifications, the Optivantage DH emphasizes workflow and safety through multi-use day-sets, auto-fill and auto-purge, syringe heating, and smart integration with CT scanners and IT systems. This combination turns the injector into a central component of efficient, high-quality CT imaging rather than just a standalone device.

What Is the Guerbet Optivantage DH Dual Head CT Injector?

The Guerbet Optivantage DH is a dual-head CT injector designed for controlled contrast media delivery in computed tomography environments. This contrast injection system enables simultaneous delivery of contrast and saline through independent syringe mechanisms, supporting advanced CT imaging protocols.

How Is the Guerbet Optivantage DH Positioned Within Modern CT Injector Portfolios?

The Optivantage DH holds FDA 510(k) clearance as a Class II medical device, cleared November 30, 2004. Manufactured by Mallinckrodt Inc., Liebel-Flarsheim Business in Cincinnati, OH, it’s classified as an Injector and Syringe, Angiographic under 21 CFR 870.1650 (product code DXT). This regulatory positioning places it among established contrast delivery platforms with proven safety and performance standards.

The device’s classification reflects its role as a workhorse contrast injection system for radiology departments requiring reliable dual-head functionality. Its clearance predates many competing systems, indicating market maturity and extensive clinical deployment history.

Which CT Imaging Environments and Patient Populations Is the Optivantage DH Designed to Serve?

The FDA indications specify use for injecting radiopaque contrast media into a patient’s vascular system to obtain diagnostic images with computed tomography equipment. The system delivers radiographic contrast media and saline at controlled flow rates and volumes for enhanced diagnostic imaging.

This broad indication supports diverse CT imaging environments—from routine diagnostic scanning to complex vascular studies. The dual head design accommodates protocols requiring precise contrast-to-saline ratios, making it suitable for standard adult populations undergoing contrast-enhanced CT examinations. The controlled delivery mechanism supports both simple and multiphase injection protocols across general radiology, emergency, and outpatient imaging settings.

How Does a Dual Head CT Injector Like the Guerbet Optivantage DH Function in Principle?

Dual head CT injectors operate through independent syringe drive mechanisms that allow separate control of contrast and saline delivery. This architecture enables precise protocol execution for advanced CT workflow optimization, supporting complex injection sequences without manual intervention.

What Does “Dual Head” Contrast Injection Enable Compared With Single Head Systems?

The Optivantage DH contains two electromechanical syringe drive systems operating independently. This enables simultaneous injection of dual protocols—contrast media and saline—through separate delivery pathways.

Single-head systems require manual changeover or sequential delivery. The dual head design eliminates these steps, allowing programmed saline flush immediately following contrast injection without technologist intervention. This reduces exam time and improves consistency across patients, particularly for vascular and multiphase CT imaging injector specs that demand precise bolus timing.

How Do Contrast and Saline Management Workflows Operate in the Guerbet Optivantage DH?

The system supports saline ratios from 10% to 70% in 5% increments, allowing precise protocol customization. Three automated features streamline workflow: auto-fill automatically loads disposable syringes, auto-purge removes air with a single button press, and auto-home retracts rams to the starting position after injection completion.

These automation features reduce setup time and minimize manual steps between patients. Technologists can program contrast-to-saline ratios based on clinical protocols, and the system executes the sequence automatically. The auto-purge function addresses air removal—a critical safety step—without requiring multiple manual manipulations. Combined, these features support high-volume CT workflow optimization while maintaining consistent injection quality.

What Core Design Features Define the Guerbet Optivantage DH Dual Head Injector?

The Optivantage DH integrates precision engineering with workflow-focused automation. Design elements address contrast temperature management, air safety protocols, and technologist efficiency across high-volume CT imaging environments.

How Is the Injector Head and Drive System Engineered for Precision and Reliability?

The system includes an integrated syringe heater maintaining contrast at 37°C, reducing viscosity for consistent flow characteristics. Tilt enable functionality requires completion of an enable sequence before injection, helping reduce air embolism risk through procedural safeguards.

Syringe compatibility spans 200 mL empty syringes and prefilled options in 50, 75, 100, and 125 mL capacities. This range accommodates both contrast preparation workflows and ready-to-use prefilled systems. The drive mechanism accommodates these varied syringe formats without manual calibration, supporting flexibility in contrast media sourcing and department protocols.

How Does the Optivantage DH User Interface Support Technologist Workflow and Protocol Control?

CAN class 4 and relay interfacing capabilities come standard, enabling integration with CT scanners and radiology information systems. This connectivity supports automated protocol selection and injection synchronization with scan acquisition.

The Timing Bolus® feature allows test injections to confirm protocol timing before diagnostic scans. Technologists can execute small-volume test boluses, observe contrast arrival timing, and then adjust main injection parameters accordingly. This optimization improves bolus timing accuracy and image quality, particularly for CT angiography and perfusion studies where millisecond-level timing affects diagnostic value.

Which Ergonomic and Physical Design Elements Support Everyday Use in CT Suites?

An optional ceiling mount configuration saves floor space while maintaining injector accessibility. This mounting option suits compact CT suites where equipment footprint directly impacts patient flow and technologist movement patterns.

Multi-use capability allows syringes and day-sets to remain in service up to 24 hours across multiple patients, reducing disposable waste and setup frequency. Available tubing options include P/N 601195 Coiled Extension Tubing (60″L, 400 psi), P/N 601227 Tubing with Male Luer Adapter (48″L, 400 psi), and P/N 600096S CT Syringe (200 mL) with Spike. These tubing configurations accommodate different patient positioning requirements and CT gantry layouts.

What Performance and Specification Details Define the Guerbet Optivantage DH Dual Head Injector as a Market Leader in CT Imaging?

CT imaging injector specs determine clinical capability and departmental throughput. The Optivantage DH delivers performance parameters supporting routine to advanced protocols while optimizing technologist efficiency through multi-use design and connectivity features.

What Are the Key Injection Performance Parameters, Such as Flow Rates, Pressure Limits, and Volume Ranges?

Flow rate range spans 0.1–10.0 mL/sec, covering low-volume pediatric protocols through high-flow CT angiography studies. Pressure limits reach 50–325 peak psi in standard configuration, with multi-use systems supporting up to 350 psi for consistent delivery across extended tubing lengths.

Syringe capacity options include 200 mL empty syringes and prefilled formats in 50, 75, 100, and 125 mL volumes. This specification range positions the contrast injection system for both high-volume adult imaging and precise low-dose applications. The 10 mL/sec maximum flow rate meets requirements for pulmonary embolism protocols and cardiac CT angiography, where rapid bolus delivery determines diagnostic quality.

How Do Timing, Phasing, and Multiphase Injection Options Support Advanced CT Protocols?

Delay time programming extends from 0–600 seconds, allowing precise synchronization between contrast injection and scan acquisition. Injection time spans the same 0–600 second range, supporting both rapid boluses and extended infusion protocols.

These timing parameters enable complex multiphase studies, including arterial, portal venous, and delayed phase liver imaging. Technologists can program scan delays matching patient-specific circulation times, particularly critical for CT angiography, where arterial enhancement timing directly affects vessel opacification quality. The 10-minute maximum injection duration accommodates CT perfusion studies requiring sustained contrast delivery during dynamic scanning.

Which Hardware and Software Specifications Enable High-Throughput CT Operations?

The multi-use system configuration delivers 64% faster workflow compared to single-patient use systems. This translates to an average of 35 minutes saved per shift, directly impacting patient throughput in high-volume departments.

Workflow acceleration stems from eliminating repeated syringe changes and system preparation between patients. The 24-hour multi-use capability means one syringe set serves multiple patients throughout a shift, reducing non-productive technologist time. For departments performing 30-40 contrast CT exams daily, the time savings compound significantly, improving scanner utilization rates and patient access.

How Do Connectivity and Integration Specifications Enhance Workflow Efficiency and Data Analytics?

Optional RFID capability provides multiple safety and efficiency benefits: prevents accidental air embolism from empty or used syringes, eliminates patient cross-contamination risk, reduces medication errors, and significantly decreases syringe preparation and labeling time.

RFID technology automates syringe identification and tracking, removing manual verification steps. The system recognizes syringe status automatically, blocking injection attempts with compromised syringes. This automated verification supports CT workflow optimization by reducing pre-injection safety checks while maintaining—or improving—safety margins. Integration with departmental systems enables automatic documentation of contrast volumes and lot numbers for quality control and adverse event tracking.

How Does the Guerbet Optivantage DH Enhance Patient and Operator Safety?

Safety mechanisms in the Optivantage DH address injection site integrity, contrast dose optimization, and error prevention. Clinical evidence demonstrates both measurable safety outcomes and high patient satisfaction rates.

What Pressure, Air, and Extravasation Safeguards Are Built Into the Optivantage DH?

The Patency Check® feature verifies proper catheter placement and vascular patency before injection initiation. This pre-injection test applies low-pressure saline to confirm IV line integrity, detecting infiltration or occlusion before high-pressure contrast delivery.

Recent clinical studies from 2025 report no adverse events with the Optivantage DH system. This safety record reflects the cumulative effect of built-in safeguards, including tilt enable sequences, air detection, and pressure monitoring. The Patency Check® function specifically reduces extravasation risk by identifying compromised IV access before contrast administration, when intervention costs are minimal and patient harm is preventable.

How Does the System Assist With Contrast Dose Management and Patient-Specific Optimization?

OptiBolusⓇ software reduces contrast media usage by up to 40% without compromising image quality. This dose optimization technology adjusts injection parameters based on patient-specific factors and examination protocols.

Contrast dose reduction directly benefits patient safety by minimizing nephrotoxicity risk and allergic reaction exposure. The 40% reduction represents a substantial clinical impact for patients with borderline renal function or contrast allergy. OptiBolusⓇ maintains diagnostic image quality through optimized injection timing and flow rate adjustments, demonstrating that lower contrast volumes can achieve equivalent enhancement when delivery parameters are precisely controlled.

Which Alerts, Checks, and Guided Workflows Help Reduce User Error Risk?

Patient satisfaction rates exceed 96% in recent clinical studies, reflecting both technical performance and procedural comfort. This metric captures the patient experience of injection quality, pain at the injection site, and overall examination tolerance.

High satisfaction correlates with consistent injection technique enabled by automated workflows and guided protocols. The contrast injection system’s standardized approach reduces operator-dependent variability, ensuring repeatable injection quality across different technologists and patient volumes. Automated checks and alerts prevent common setup errors, allowing technologists to focus on patient interaction rather than equipment troubleshooting.

How Does the Guerbet Optivantage DH Integrate With CT Scanners and Radiology IT Systems?

Integration capabilities determine how effectively the dual head CT injector functions within broader imaging workflows. The Optivantage DH employs standard connectivity protocols to enable automated protocol selection, synchronized acquisition, and documentation.

What Connectivity Options and Communication Standards Are Supported by the Optivantage DH?

Standard CAN class 4 and relay interfacing enable direct communication with CT scanner consoles and radiology information systems. These connectivity standards support bidirectional data exchange, allowing the injector to receive protocol parameters from the scanner and transmit injection status back to imaging systems.

CAN bus architecture provides reliable real-time communication essential for synchronized injection and scan timing. Relay interfaces offer compatibility with legacy CT systems lacking advanced digital connectivity, ensuring the contrast injection system integrates across diverse equipment fleets. This dual-mode connectivity extends injector lifespan across CT scanner upgrades and replacements.

How Does Injector–Scanner Synchronization Improve Bolus Timing and CT Image Quality?

The Timing Bolus® feature integrates with CT scanner triggering to optimize contrast arrival timing. Test injection sequences feed timing data directly into scan delay calculations, eliminating the need to manually transfer bolus-tracking measurements.

Automated synchronization reduces timing variability between contrast administration and scan acquisition. The injector communicates injection start signals to the CT scanner, enabling precise delay countdown and automated scan triggering at peak enhancement. This integration particularly benefits CT angiography protocols where sub-second timing differences affect arterial opacification quality and diagnostic confidence.

How Can Injection Data Be Captured for Quality Control, Reporting, and Billing Workflows?

Integration with radiology IT infrastructure enables automated documentation of contrast volumes, injection pressures, and protocol parameters. These data points flow to PACS, RIS, and quality management systems without manual entry.

Captured injection data supports multiple workflow requirements: contrast volume documentation for billing accuracy, pressure limit tracking for quality assurance programs, and adverse event correlation when complications occur. Automated data capture eliminates transcription errors and reduces technologist documentation burden, supporting CT workflow optimization while maintaining complete procedural records.

In Which CT Clinical Applications Does the Guerbet Optivantage DH Demonstrate Particular Strengths?

Clinical versatility stems from the Optivantage DH’s specification range and programmability. The contrast injection system adapts to protocols spanning high-flow vascular imaging through conservative dose management for at-risk populations.

How Does the Optivantage DH Support Angiographic and Vascular CT Examinations?

The 0.1–10.0 mL/sec flow rate range and 350 psi pressure capability support both peripheral and central vascular protocols. High-flow delivery at 10 mL/sec enables tight contrast boluses essential for CT angiography, while pressure limits maintain consistent flow through extended catheter lengths.

Vascular imaging demands rapid, high-volume contrast delivery to achieve arterial opacification before venous contamination. The dual head design allows immediate saline flush following contrast bolus, sharpening the bolus edge and reducing contrast volume requirements. Timing Bolus® functionality optimizes scan delays for patient-specific circulation times, critical when imaging varies from carotid arteries to lower extremity runoff studies.

How Does the System Handle Cardiac, Multiphase Liver, and Perfusion CT Protocols?

Programmable delay and injection times spanning 0–600 seconds accommodate complex multiphase protocols. Cardiac CT requires precise timing between injection and acquisition during specific cardiac phases, while liver imaging demands sequential arterial, portal venous, and delayed phase acquisitions.

The dual-head architecture supports split-bolus techniques and biphasic injection profiles used in advanced hepatic imaging. Extended injection duration capability suits CT perfusion studies requiring sustained contrast delivery during dynamic scanning sequences. Protocol flexibility allows adaptation to patient-specific factors, including cardiac output and body habitus, without hardware limitations.

How Can the Injector Be Tailored for Pediatric, Low-Dose, and Renal-Risk Patient Imaging?

OptiBolusⓇ software, which reduces contrast volumes up to 40% directly benefits dose-sensitive populations. Pediatric patients and those with renal insufficiency require minimum effective contrast doses, making dose optimization technology clinically valuable.

The lower flow rate range (0.1 mL/sec minimum) and small prefilled syringe options (50 mL) support precise low-volume protocols. Fine flow rate control enables gradual injection suitable for small-gauge pediatric IVs, while dose reduction algorithms maintain diagnostic quality at reduced volumes. This combination addresses both contrast nephropathy concerns and pediatric radiation dose management through CT workflow optimization that prioritizes patient safety without compromising diagnostic yield.

How Does the Guerbet Optivantage DH Compare With Other Dual-Head CT Injectors on the Market?

Competitive differentiation emerges through workflow features, technical specifications, and operational models. Direct comparison reveals where the Optivantage DH delivers unique capabilities versus specification parity with competing systems.

In Which Specification Areas Does the Optivantage DH Typically Outperform Comparable Systems?

Multi-use capability allowing 24-hour syringe and day-set use is unique to the Optivantage DH among major competitors. This operational model differentiates it from single-patient-use systems, including the Bayer MEDRAD Stellant FLEX and Bracco Empower CTA+.

The multi-use system supports pressure limits up to 350 psi versus 325 psi for the Bayer MEDRAD Stellant FLEX. OptiBolusⓇ technology, reducing contrast volumes up to 40% represents another exclusive feature absent in competing Bayer and Bracco systems. These advantages translate to measurable workflow gains—64% faster operation and 35 minutes saved per shift—that compound across high-volume departments. Contrast dose reduction addresses both cost containment and patient safety priorities increasingly central to CT imaging protocols.

Where Are Performance and Feature Differences Most Dependent on Site-Specific Configuration?

Optional features, including ceiling mount configuration and RFID capability, allow customization to department-specific needs. These additions modify the baseline system without changing core injection performance.

Flow rate specifications show parity: both Optivantage DH and Bayer MEDRAD Stellant FLEX deliver 0.1–10.0 mL/sec. Core injection parameters overlap across competing dual-head CT injectors, making operational features and workflow integration the primary differentiators. Site-specific factors—suite layout, patient volume, contrast management preferences—determine which optional features deliver value. Departments prioritizing space efficiency benefit from ceiling mounts, while high-volume centers gain more from RFID-enabled multi-use workflows.

How Do Ownership Costs, Disposables, and Service Models Influence Overall Value?

Total cost of ownership extends beyond acquisition price to encompass disposable consumption, service contracts, and operational efficiency gains. Multi-use systems reduce disposable costs by extending syringe use across multiple patients.

Labor efficiency represents another cost dimension: time savings of 35 minutes per shift translate to improved scanner utilization or reduced technologist overtime. Contrast savings from OptiBolusⓇ technology compound over thousands of annual examinations. Service model considerations include preventive maintenance frequency, parts availability, and technical support responsiveness. Evaluation requires modeling site-specific volumes, contrast costs, and labor rates to determine net operational savings versus competing CT imaging injector specs and ownership structures.

Partner With Us to Advance Your CT Workflow

At Hitech Global Medical Services Co., we know that choosing the right CT injector is critical to image quality, patient safety, and day-to-day efficiency. The Guerbet Optivantage DH brings together dual head performance, multi-use efficiency, and advanced safety tools like Patency Check® and OptiBolusⓇ to strengthen every step of your CT workflow.

We work with you to configure features such as Timing Bolus®, CAN connectivity, RFID tracking, and 24-hour day-sets around your specific protocols and volumes. If you are considering an upgrade or standardizing injection platforms, we invite you to connect with us at Hitech Global Medical Services Co. so we can help you design a faster, safer, and more patient-centered CT imaging service.